DECLARE
DECLARE — define a cursor
Synopsis
DECLARE name [ BINARY ] [ ASENSITIVE | INSENSITIVE ] [ [ NO ] SCROLL ]
CURSOR [ { WITH | WITHOUT } HOLD ] FOR query
Description
DECLARE
allows a user to create cursors, which can be used to retrieve a small number of rows at a time out of a larger query. After the cursor is created, rows are fetched from it using FETCH
.
Parameters
name
The name of the cursor to be created.
BINARY
Causes the cursor to return data in binary rather than in text format.
ASENSITIVE
INSENSITIVE
Cursor sensitivity determines whether changes to the data underlying the cursor, done in the same transaction, after the cursor has been declared, are visible in the cursor. INSENSITIVE
means they are not visible, ASENSITIVE
means the behavior is implementation-dependent. A third behavior, SENSITIVE
, meaning that such changes are visible in the cursor, is not available in ProtonBase. In ProtonBase, all cursors are insensitive; so these key words have no effect and are only accepted for compatibility with the SQL standard.
Specifying INSENSITIVE
together with FOR UPDATE
or FOR SHARE
is an error.
SCROLL
NO SCROLL
SCROLL
specifies that the cursor can be used to retrieve rows in a nonsequential fashion (e.g., backward). Depending upon the complexity of the query's execution plan, specifying SCROLL
might impose a performance penalty on the query's execution time. NO SCROLL
specifies that the cursor cannot be used to retrieve rows in a nonsequential fashion. The default is to allow scrolling in some cases; this is not the same as specifying SCROLL
.
WITH HOLD
WITHOUT HOLD
WITH HOLD
specifies that the cursor can continue to be used after the transaction that created it successfully commits. WITHOUT HOLD
specifies that the cursor cannot be used outside of the transaction that created it. If neither WITHOUT HOLD
nor WITH HOLD
is specified, WITHOUT HOLD
is the default.
query
A SELECT
or VALUES
command which will provide the rows to be returned by the cursor.
The key words ASENSITIVE
, BINARY
, INSENSITIVE
, and SCROLL
can appear in any order.
Notes
Normal cursors return data in text format, the same as a SELECT
would produce. The BINARY
option specifies that the cursor should return data in binary format. This reduces conversion effort for both the server and client, at the cost of more programmer effort to deal with platform-dependent binary data formats. As an example, if a query returns a value of one from an integer column, you would get a string of 1
with a default cursor, whereas with a binary cursor you would get a 4-byte field containing the internal representation of the value (in big-endian byte order).
Binary cursors should be used carefully. Many applications, including psql, are not prepared to handle binary cursors and expect data to come back in the text format.
When the client application uses the “extended query” protocol to issue a FETCH
command, the Bind protocol message specifies whether data is to be retrieved in text or binary format. This choice overrides the way that the cursor is defined. The concept of a binary cursor as such is thus obsolete when using extended query protocol — any cursor can be treated as either text or binary.
Unless WITH HOLD
is specified, the cursor created by this command can only be used within the current transaction. Thus, DECLARE
without WITH HOLD
is useless outside a transaction block: the cursor would survive only to the completion of the statement. Therefore ProtonBase reports an error if such a command is used outside a transaction block. Use BEGIN
and COMMIT
(or ROLLBACK
) to define a transaction block.
If WITH HOLD
is specified and the transaction that created the cursor successfully commits, the cursor can continue to be accessed by subsequent transactions in the same session. (But if the creating transaction is aborted, the cursor is removed.) A cursor created with WITH HOLD
is closed when an explicit CLOSE
command is issued on it, or the session ends. In the current implementation, the rows represented by a held cursor are copied into a temporary file or memory area so that they remain available for subsequent transactions.
WITH HOLD
may not be specified when the query includes FOR UPDATE
or FOR SHARE
.
The SCROLL
option should be specified when defining a cursor that will be used to fetch backwards. This is required by the SQL standard. However, for compatibility with earlier versions, ProtonBase will allow backward fetches without SCROLL
, if the cursor's query plan is simple enough that no extra overhead is needed to support it. However, application developers are advised not to rely on using backward fetches from a cursor that has not been created with SCROLL
. If NO SCROLL
is specified, then backward fetches are disallowed in any case.
Backward fetches are also disallowed when the query includes FOR UPDATE
or FOR SHARE
; therefore SCROLL
may not be specified in this case.
Scrollable cursors may give unexpected results if they invoke any volatile functions. When a previously fetched row is re-fetched, the functions might be re-executed, perhaps leading to results different from the first time. It's best to specify NO SCROLL
for a query involving volatile functions. If that is not practical, one workaround is to declare the cursor SCROLL WITH HOLD
and commit the transaction before reading any rows from it. This will force the entire output of the cursor to be materialized in temporary storage, so that volatile functions are executed exactly once for each row.
If the cursor's query includes FOR UPDATE
or FOR SHARE
, then returned rows are locked at the time they are first fetched, in the same way as for a regular SELECT
command with these options. In addition, the returned rows will be the most up-to-date versions.
It is generally recommended to use FOR UPDATE
if the cursor is intended to be used with UPDATE ... WHERE CURRENT OF
or DELETE ... WHERE CURRENT OF
. Using FOR UPDATE
prevents other sessions from changing the rows between the time they are fetched and the time they are updated. Without FOR UPDATE
, a subsequent WHERE CURRENT OF
command will have no effect if the row was changed since the cursor was created.
Another reason to use FOR UPDATE
is that without it, a subsequent WHERE CURRENT OF
might fail if the cursor query does not meet the SQL standard's rules for being “simply updatable” (in particular, the cursor must reference just one table and not use grouping or ORDER BY
). Cursors that are not simply updatable might work, or might not, depending on plan choice details; so in the worst case, an application might work in testing and then fail in production. If FOR UPDATE
is specified, the cursor is guaranteed to be updatable.
The main reason not to use FOR UPDATE
with WHERE CURRENT OF
is if you need the cursor to be scrollable, or to be isolated from concurrent updates (that is, continue to show the old data). If this is a requirement, pay close heed to the caveats shown above.
The SQL standard only makes provisions for cursors in embedded SQL. The ProtonBase server does not implement an OPEN
statement for cursors; a cursor is considered to be open when it is declared. However, ECPG, the embedded SQL preprocessor for ProtonBase, supports the standard SQL cursor conventions, including those involving DECLARE
and OPEN
statements.
Examples
To declare a cursor:
DECLARE liahona CURSOR FOR SELECT * FROM films;
See FETCH for more examples of cursor usage.
Compatibility
The SQL standard allows cursors only in embedded SQL and in modules. ProtonBase permits cursors to be used interactively.
According to the SQL standard, changes made to insensitive cursors by UPDATE ... WHERE CURRENT OF
and DELETE ... WHERE CURRENT OF
statements are visible in that same cursor. ProtonBase treats these statements like all other data changing statements in that they are not visible in insensitive cursors.
Binary cursors are a ProtonBase extension.